FB体育app官网

EPC Products Education Biochemical Engineering BE3 Anaerobic Column Reactor
产品中心
BBS|Hot Topic
BE3 Anaerobic Column Reactor

Model:BE3

Use:

Standard:

Related Products
Description
The Anaerobic Column Reactor BE3 features a tall, slender, cylindrical glass column in two sections, each section with a heating jacket. At
the top of the column, a third unheated section collects the gas and provides an efuent overflow. Between the two heated sections is
a manifold, which provides ports for instrumentation, sampling and dosing. The feed into the reactor is provided by a variable-speed
peristaltic pump.
The temperature of the column contents can be controlled by circulating warm water through the jackets of the lower two sections.
The water is heated in a heating tank, using an electric heater and distributed by a recirculation pump using PID control. Typically the
reactor temperature is set to 35°C to suit the anaerobic bacteria in the
feedstock.
The column contents can be recirculated from the top section to the bottom section using a variable speed pump. The recirculation can
also be used to fluidise a bed of media (eg pumice) used to support the growth of biomass. Alternatively the column can be operated as an
expanded granular sludge bed reactor (EGSB) with no media flling.
A novel feature of the new Anaerobic Reactors is the gas collection system. This enables the rate of gas emission to be accurately measured
over long periods of time. This occurs even when very low quantities of gas are produced, while retaining low back pressure in the system so as
not to inhibit the release of the gases. It operates by collecting a known volume of gas over water. When the collection tank is full the gas is
automatically discharged and the water replaced. The PLC counts the number of cycles to measure the total volume of gas and measures the
time between discharges to calculate the flow rate.
The reactor is supplied complete with a pH dosing system. This comprises two peristaltic pumps under control of the PLC, used to add
a base solution or an acid solution to the reactor as appropriate. The user can defne the range of pH values to be maintained.
Storage positions are provided for standard fve-litre chemical jars, enabling the dosing solutions to be prepared in advance and left
in place throughout the process, minimising the need to handle potentially harmful chemicals.
As well as the gas collection rate and volume, further instrumentation measures the reactor temperature, pH, water temperature and the
recirculation flow.

This data can all be recorded on a PC using the data logger.


Specifcations
Reactor volume 9l
Heater power 2kW
Jacket temperature < 60°C
Flow rate (Recycle) 15 l/min
Feed flow rate 0.06 to 4.81 l/hr
Settler volume N/A



Project Case
Solution
Download